CV, Electrical Engineer With Experience Of Telecoms Sector And Other

Available
Serial No: 31504
Skills keywords: electrical engineer, facility managemnet, operation & maintenance, power specialist, team lead, telecom power engineer

Short Bio:

• AC & DC power.
• Electrical circuits design and panels (ATS, MOR, MDB, SMDB, DB, Panels, LT, DOL, Star Delta,).
• To attend and resolve complaints related to power supply system at MSC, MGW, BSC, BTS sites, call centers and banks.
• Operation and maintenance of switch gear.
• Operation & maintenance of transformer from 25KVA to 4000KVA.
• Generators (DG) maintenance from 10 KVA to 6000 KVA of different brands like CAT, Cummins, Perkins, John Deere, Detroit, Denyo, Kubota, Volvo etc.

Current location:  Punjab, Pakistan - View on map
Nationality: Pakistani
Preferred Sector of Employment:  , Oil, Gas and Energy, General Management
Spoken languages: english, Udru
Location I am interested in working: Anywhere

Objective

To pursue stirring career in a dynamic organization offering challenges and opportunities for mutual growth and scale new heights.

Strengths

• AC & DC power.

• Electrical Circuits design and Panels (ATS, MOR, MDB, SMDB, DB, Panels, LT, DOL, Star Delta,).

• To attend and resolve complaints related to power supply system at MSC, MGW, BSC, BTS sites, Call Centers and Banks.

• Operation and maintenance of Switch gear.

• Operation & maintenance of Transformer from 25KVA to 4000KVA.

• Generators (DG) maintenance from 10 KVA to 6000 KVA of different brands like CAT, Cummins, Perkins, John Deere, Detroit, Denyo, Kubota, Volvo, etc.

• TG Shinko.

• Modules of different types like DATACOM, Deep Sea, Power Tech, CAT, Cummins, SDMO, METS, John Deer, Siemens and Impac etc.

• UPS Libert (Emerson), Huawei (UPS2000), Kelong, Inverters (ABB, Commander, Focus & Siemens).

• Rectifiers Siemens, Eltek, Delta, Power one, Emerson, Huawei.

• Rectifier Power supply system Siemens PS-900.Emerson PS48600-3B/2900.

• Emerson PS481000-5/100. Emerson PS48300, Huawei Power cube1000, Huawei TP483000.

• Motors different types (Induction, Slip ring and Synchronous motor).

• Air Conditioning System/HVAC.

• Fire detection and suppression system.

• Grounding system.

• Centralize reporting.

• Monitoring Gem and GLO/BSB and RMS systems.

• Control refueling and fuel consumption. Prepare plan and monitor plan execution.

• Prepare daily report and monthly report and share with customer and concerns.

• Team Management and follow up for timely fault rectification

• Monitoring the site outages on Net Act/M 2000 terminal in parallel, providing back support to BSS Team.

• To make sure to minimize the outage by taking proactive decision/ managing available resources, in order to maintain KPI’s. Supervising and cross check the PM/CM issues. (Comparing the CM with PM) and afterwards pushing to team to perform better by taking necessary actions.

• Follow up with different subcons regarding major OH, Rental DG’s, parts & pending issues.

• Supervision of installation/erection.

• Serve as an interface towards sub-contractors, implementation department, real estate department, administration department, security, vendor team doing maintenance & installations etc.

• Facilities management.

• Process understanding. Interpersonal skill. Reporting skill. To ensure the implementation of Security, HSE and QA/QC policies.

• Sound knowledge of warehouse.

• Ability to handle other team`s in tactful manner, ensuring enforcement of O&M procedures and policies.

Projects

• Mobilink, Wincom (Warid Telecom), World Call, Wateen, Telenor, Pakistan Telecommunication Mobile LTD in across the Pakistan.

• Banks and call centers.

• Erection of Mill House (In Shakarganj Mills Ltd. Jhang)

• Erection of Distillery Plant ( In Shakarganj Mills Ltd. Jhang

• Erection of an Hydrous Plant ( In Shakarganj Mills Ltd. Jhang )

• Erection work of 15 MW Power Plant (In Shakarganj Mills Ltd. Jhang).

Professional Experience

Currently working in Pakistan Mobile Telecommunication Limited (Etisalat)
From July 2013 to till date
As Sr. Executive Technical support Power and Environment in Lahore.

Responsibilities:

• To ensure network availability as per assigned KPI.

• Responsible to execute Preventive Maintenance and Corrective Maintenance of Power & Environment entities at core locations MSC/MGW and BSCs.

• Following are the entities covered under preventive maintenance, corrective maintenance and operation.

a. Transformers & 11KV Switchgears System.

b. Diesel Generators

c. L.T, ATS, MOR, Main DB Panels

d. Air Conditioning System

e. Grounding System

f. Fire Suppression System

g. Circuit Breakers, Magnetic Contactors & Other Protection Systems

h. Rectifier, UPS, Inverters and associated battery banks

i. External Alarms System

• Responsible to ensure effective implementation of SOP at BSCs, MSC/MGW Locations.

• Battery health/ discharge test and replace week/faulty cells.

• Responsible to ensure all activities should be executed as per stipulated documents work instructions.

• Conduct survey for new requirement and upcoming installation. Engage vendors to perform routine and emergency activities.

• Make sure smooth operation of above mentioned equipment.

• To check appropriateness of all Outdoor/Tower installations.

• To ensure the maintenance & tracking of spares & R&R.

• To ensure proper coordination with vendor and sub-contractor and to provided support where required.

• Ensure ATPs are conducted as per test protocols, procedures defined in SOPs and proper maintenance of ATP database.

• Ensure effective enforcement of organization’s HSE and QA/QC policies.

• Conduct sites audit and take necessary steps for improvement of system.

• Fuel bench marking of core locations.

• Prepare documentation for recertification of ISO 9001:2008.

• Conduct training of manning staff where necessary.

• Prepare RCA of incidents and take corrective action.

Worked in Zhongxing Telecom Pakistan (ZTE)
From July 2012 to Apr 2013
As Team Lead.

• Prepare plan of DG and Air Cons PM and make sure execution as per plan.

• Ensure network availability 24/7.

• Follow up with CM and refueling teams to minimize outages.

• Prepare plan for refueling of sites.

• Prepare report of fueling activities on daily basis, weekly, monthly and share with all stakeholders.

• Prepare GLO/ BSB tracker and update to concerns.

• To insure fuel saving at Gadgets sites.

• To insure fuel alarm monitoring and take action as per requirement.

• Monitor alarms and coordination with other teams.

• To insure commercial power issues rectification in timely.

• Take up security issues with security teams and its follow up.

• Conduct joint visits at sites with security teams and operation team for bench marking and for other issues.

• For proper operation of GLO/BSB sites coordination with other teams.

• Monitor GEM. RMS and RTU operation, maintenance and update to concerns.

• To insure timely movements refueling of teams.

• To insure perform activities as per SLA.

• To ensure network availability as per assigned KPI.

• Resource management in case of new hiring.

• To insure implementation of HSE policies.

Worked in Extreme Engineering Solutions (PVT) Ltd
From July 2011 to June 2012
As Regional Manager Core locations Telenor project CII.

Responsibilities:

• Ensure that network availability KPIs are met per assigned targets.

• To insure smooth operation of core locations.

• To insure daily checking of DGs 250kva to 1000kva ratings.

• Prepare plan of air conditions PM and execution.

• Make sure timely refueling of DGs.

• Prepare quarterly PM plan of Panels, transformer, earthing, raise floor and insure implementation.

• To make sure timely PM activities of DGs.

• Store audit of DGs vendor and make sure arrangements of necessary parts.

• To insure proper alarms working.

• Generate TT# and close it as per SLA for CM activities.

• To insure faulty rectification timely.

• Prepare daily, weekly and activity report and share to customer

• Supervision of fire extinguisher system’s PM/CM activities installed at core locations.

• Responsible for meeting the targets assigned by management.

• To identify, escalate & resolve issues that cause or likely to cause any deviation in meeting assigned targets.

• Prepare monthly demands of consumable, parts and share to concerns and follow up for availability.

Worked in Nokia Siemens Network (NSN) Jhang, Pakistan
From June 2010 to June 2011
As Operation Officer Power Infrastructure

Responsibilities:

• Ensure that network availability KPIs are met per assigned targets.

• Perform PM/CM activities of DC power systems installed at MGWs.

(Rectifiers, Inverters, Battery banks, UPS)

• Monitor PM/CM activities of DGs and ACs installed at MGWs.

• Ensure quarterly PM of fire system installed at MGWs.

• To ensure completion of PM cycle in timely of BTS, HUBs, DWDMs, BSCs.

• Conduct audit of sites for verification of PM/CM activities and make sure quality work as per standard.

• Conduct store visits of subcon and make sure availability of parts and share report to concerns.

• Address the root cause of outages and make strategy to overcome issues.

• Monitor daily alarms and take actions as per necessary.

• Monitor GEM installation, operation and perform trouble shooting where necessary.

• Analysis of fuel consumption and forward to security teams if necessary.

• Ensure installation proper quantity of rectifies at sites.

• Ensure standard OH of DGs from subcon, check after OH and conduct joint visit with TP and subcon for acceptance.

• Verification of parts and invoices.

• To ensure timely rectification of commercial power issues.

• To ensure HSE compliance.

• Conduct weekly meeting with sub-con and client.

Worked in Telenor Pakistan (Jhang)
From June 2009 to Jun 2010
As Officer Field Operation Power Infrastructure.

Responsibilities:

• Ensure that network availability KPIs are met per assigned targets.

• Supervision to PM/CM activities of AC and DC system installed at MGWs, BSCs, DWDM, HUB and BTS sites.

• Make sure quality work.

• Maintain appliances in healthy condition installed at MGWs.

• Conduct audit of sites for PM/CM activities and share reports to concerns.

• Share report of audit and follow up issues rectification.

• Monitor refueling activities.

• Verification of OH list shared from subcon.

• After OH conduct joint visit for acceptance and share report.

• Tracking of snags.

• Supervision of civil works.

• Take up security issues with security team.

• Conduct the meeting with NSN and subcon to achieve better TCH availability.

• Conduct store audit of subcon.

• To ensure quality parts replacements at sites.

• To ensure HSE standard.

• Monitor commercial issues, suggestion for new installation, conduct survey and make sure quality work.

• Verification of commercial issues

• Verification of parts and invoices.

Worked in Wincom (Warid Telecom)
As Supervisor Electrical Operation and maintenance in Faisalabad
From 1st July 2008 to June 2009.

Responsibilities:

• Supervision of preventative maintenance and corrective maintenance of BTS, HUB and BSC sites of region (500 sites).

• Ensure activities as per SLA.

• Ensure that network availability KPIs are met per assigned targets.

• Conduct meetings with sub-con and customer, to identify, escalate & resolve issues that cause or likely to cause any deviation in meeting assigned targets.

• Verification of parts and invoices.

• Monitor commercial power issues and rectification.

• Monitor VTDC installation and operation.

• Monitor refueling activites.

• Tracking of OH snags.

• Follow up with teams to close outages.

• Troubleshoot and support to teams where necessary.

Service Engineer in Hightech Electric Engineering & Services
Oct 2006 to March 2008.

Responsibilities:

• Supervision of operation and maintenance issues and provide backup support where necessary.

• Managing teams (70 to 80 guys), cash arrangement, vehicles and transportation issues.

• Preparing demand of parts for monthly O&M activities and insure timely delivery.

• Conduct meetings with customers Waird, Wateen World call and Banks.

As Supervisor in Shakarganj Mills Ltd. Jhang
From Oct 2004 to Oct 2006.

Responsibilities/Role:

• Insure smooth operation of Process house, Mill house, Boiler house, Filter house and Distillery plant.

• Trouble shoot the machines.

• Overhauling of motors from 0.5 HP to 1000 H.P.

• Maintenance of switchgears.

• Designing electrical systems and circuits, as well as contributing to improved designs and manufacturing processes are other common job functions.

• Motivate electricians/subordinates to increase their productivity and meet work goals.

• Erection of new/expansion system.

• Support power house team where necessary.

• Coordinate with others departments to make objectives smooth and achieve common goals.

 

• 3 years apprenticeship training
From July 2001 to July 2004 in Shakarganj Mills Ltd. Jhang

 

IT Skills

Computer Knowledge in general and specifically in Microsoft product (Office Excel, Word, PPT), Microsoft Visio.

Academic Record

• Bachelor of technology in Electrical from Preston University Pakistan with CGPA 3.0.

• Diploma of Associate Engineering in Electrical from Punjab Board of Technical Education Lahore with 1st division 69.7% marks.

• Matric with science from Faisalabad Board with 2nd division aggregate 56% marks.

• One year training certificate in Electrical from Govt. ATC Faisalabad.

• IELTS with 5.5 bands.

 






popup-img